RAUFRIGO cooling pipe system

The pre-insulated pipe system for transporting coolants, cooling brines or process media.

RAUFRIGO cooling pipe system from REHAU

RAUFRIGO cooling pipe system

The pre-insulated pipe system for transporting coolants, cooling brines or process media.

 

RAUFRIGO cooling pipe system. Pre-insulated, for large spans

The RAUFRIGO cooling pipe is made of polymer material, insulated with rigid polyurethane foam and finally coated with a rigid folded spiral-seam tube. The system is used in production, industrial refrigeration, air conditioning, freezing systems, refrigerated warehouses, solar systems, outdoor and indoor installation and much more. Broad spans can be achieved due to the low weight and the rigid design of the RAUFRIGO cooling pipe.
 

Benefits


Icon: Tick

Large spans

Rigid pipe construction for large spans


Icon: tool

Material properties

Low linear expansion compared to polymer pipes, high mechanical strength


Icon: tool

Fast installation

Simple jointing technique, suitable for standard bracket clamps (no need for cold clamps)


Almost completely pre-insulated RAUFRIGO standard pipe


Almost completely pre-insulated
The RAUFRIGO standard cooling pipe is supplied pre-insulated in a total length of 6 metres. The pipe ends are exposed to establish the connection.

RAUFRIGO pipes running along the ceiling


Low weight
The duct bundle with a polymer carrier pipe results in a low overall weight. This has advantages for the dimensioning and number of suspensions and makes installation easier.

Low linear expansion of the RAUFRIGO standard pipe


Low linear expansion
The RAUFRIGO standard cooling pipe has an average linear thermal expansion coefficient of 0.015 mm/mK. With a pipe length of 30 metres and a temperature difference of 20K, this results in a change in length of only 9 millimetres.

6 m span of the RAUFRIGO standard version


Large spans possible
The maximum span of the RAUFRIGO standard version is 6 metres. This is achieved when the insulating sleeve is additionally riveted as reinforced insulation with PUR shroud foam. The standard insulation with PUR shroud foam has a span of 3 metres.

RAUFRIGO pipes are fastened with standard bracket clamps


No cooling clamps required
Do away with costly cooling clamps for these cooling pipe system. RAUFRIGO pipes can be fastened flexibly with standard bracket clamps, as these rest on the outer jacket of the insulation.

Products

 

 

Pre-insulated cooling pipe system RAUFRIGO

For the transport of coolants, cooling brines and other industrial media

RAUFRIGO cooling pipes consist of a base pipe made of PE 100, to DIN 8074/75, in black, a rigid polyurethane foam insulation and a galvanised folded spiral-seam tube as a rigid outer casing. The folded spiral-seam tube has an additional vapour barrier incorporated into the rebate. The REHAU electrofusion coupler is used for the jointing technique. As soon as the connection is made and the pressure is tested, they can be insulated using insulation sleeve and polyurethane shroud foam.

Benefits

  • Temperature-resistant from -40°C to +50°C
  • Standard, PE and FW pipe variants
  • Extensive range of fittings for joining pipes
  • Prefabricated insulation sleeves subsequently insulate the electrofusion fitting joint quickly using PUR shroud foam

 

Downloads

ePaper download portal

Digital product catalogue 

 

Accessories

FUSAPEX T-piece Generation ll


FUSAPEX 

The electrofusion coupler – temperature-resistant up to +95°C.

To product

SMARTFUSE electrofusion coupler


SMARTFUSE

The electrofusion coupler up to +50°C.

To product

Accessories and spare parts from REHAU


Accessories and spare parts

Matching accessories and available spare parts can be found here in the overview. 

To products

 

Downloads 

 

View from four different screens: smartphone, tablet, notebook and PC

Documents for download

 

Instruction manuals, handbooks, technical information, catalogues, price lists and certificates are available for download.

ePaper download portal

News

South quay 2 - 96349
06.08.2025 Key Considerations when Specifying Commercial Plumbing Systems

Growing demand for commercial projects has led to further scrutiny on all building services, with a drive for faster, more efficient installations with assured, long-lasting performance. Here we explore the implications for plumbing system specification. 

image002 - 100082615
28.07.2025 Ambient loop heat networks - how REHAU can help

There is always a debate about 4th vs 5th generation district heating, and which is the best approach but there is no one size fits all solution. We typically assume 5th generation being a direct progression of the 4th but there are in fact some very significant differences and these can even be used together. 

IGT_0709 - 100000336
15.05.2025 REHAU Expands Commercial Plumbing and Heating Sales Team

REHAU UK, building solutions division has appointed Matthew Edney to Regional Sales Manager for the South of England, with a focus on expanding its commercial plumbing and heating solutions product category. 

Engineering progress

Enhancing lives

Maximum cart size of 3 items has been reached!

Your sample cart items:
Type
Decor
Collection